Atyanta Needle Holder Assorted is a single spring instrument with a plier handle grip that curves inward at the bottom and features a
ratchet lockingmechanism at the base of the handles that can be easily squeezed to be locked and unlocked. - Maitheu is used to grasp & guide the needle while suturing - Multiposition Ratchet provides controlled grip - Spring action between the holding parts facilitates quick working ,hence is time saving - Mainly used for lace back wire tightening in orthodontics Uses: - Used to push the stretched interdental separator in the interdental area to make some space for the molar band - Its a tool for laceback wire tightening in orthodontics - Wire twisiting when making a fix retainers for lower anterior teeth
Features:
1) Ergonomic Design - Finger - Ring instrument - Needle holder - Excellent Design - For Comfortable grip - Light Weighted - Less Fatique 2) Spring action - Spring action between the holding parts facilitates quick working, hence saves time 4) Use - Commonly for laceback wire tightening in orthodontics - For holding needle 5) Material - Made of high grade Stainless steel 6) Rust Free \- Corrosion Resistant - Passivated 7) Disinfection - Autoclavable at 135 degree celsius Technical Specifications :
Instrument Name
Mathieu needle holder
Type
Dental needle holder
Category
Orthodontics
Material
Stainless Steel
Disposable / Reusable
Reusable
Sterile / Non-Sterile
Non - Sterile
Latex / Latex - free
Latex Free
Key Specifications:
Rusting Prevention
Passivated
Ultrasonic cleaned
Yes
Usage
Right & Left hand
Test Performed
Boil Test, Performance Test, Shape Test
Packing
Pouches
Manufacturer
CE & ISO Certified
Maintenance Instructions:
Must clean after every use with warm water to remove blood , tissues and mucus from the instruments
Ultrasonic cleaning is recommended for all the instruments specially articulated instruments such as forceps, rongeurs, etc
Use only standard and reputed brand of disinfectant solutions.
Sterilization:
We recommend that the temperature does not exceed 120C
Dry heat sterilization see that temperature does not exceed 180C and there should be no long exposure as this would cause discoloration, loss of temper and this in turn would disturb the hardening of the instrument
Do not use substandard chemicals or disinfectants as they can damage the instruments
Avoid use of unsuitable highly acidic chlorine containing agents
Use Demineralized water only